Voltage Range : 150/300/500 Vrms Current Range : Model 66201 - 0.01/0.1/0.4/2 Arms Model 66202 - 0.01/0.1/0.4/2 Arms ; 0.2/2/8/20 Arms Frequency Range : DC, 15Hz~10kHz Embedded high speed DSP, 16 bits Analog/Digital converters 10 mA minimum current range & 0.1mW power resolution Meets ENERGY STAR / EN 50564:2011/IEC 62301:2011 / ErP measurement requirements Accumulated energy methods for unstable power measurement User-define criteria provides automatic PASS/FAIL indications Half rack width and 2U height, suitable for system integration Dual current shunt design provides high accuracy over a wide current range (Model 66202) THD and user-specify order distortion measurement (Model 66202) Inrush current and energy measurement (Model 66202) Interface options : USB or USB+GPIB Voltage/ Current harmonics measurement up to 50 orders
Chroma 66202 Power Meter meets EN 50564:2011/IEC 62301:2011 requirement for power measurement EN 50564:2011 (derived from IEC 62301:2011) is the latest standard for defining requirements for the measurement of low power consumption for electrical and electronics household and office equipment. Chroma 66202 Power Meter is capable of meeting EN 50564:2011 requirements for power measurement instrument in accordance to section B.2.1 regarding instruments for power measurements. In addition to that, Chroma 66202 Power Meter is also capable of meeting the power measurement uncertainty requirements stated in section 4.4.1 as the power meter has verified by KEMA in accordance to IEC 62301:2005, and with the newly confirmed power measurement accuracy specification 0.1% of reading + 0.05% of range (for 300V x 100mA range), the power uncertainty contributed by 66202 Power Meter is less than the absolute power uncertainty 0.02W. The new standard has included interpretation, calculation and implementation methods for analyzing the measured power and the analyzing process is complex and time consuming. In order to resolve this, the 66202 Power Meter Softpanel has included the required data analysis feature and provide users with easy to use interface to carry out the standby power measurement according to the international standard. The Softpanel measures and provides test report feature for recording all the key parameters such as Total Harmonics Distortion (THD), waveform crest factor, voltage, current, frequency, active power, apparent power, power factor, etc.
Chroma 66202數(shù)位功率表符合EN50564:2011/ IEC62301:2011標(biāo)準(zhǔn)針對(duì)功率量測(cè)要求 EN 50564:2011為標(biāo)準(zhǔn)針對(duì)家電類及辦公室使用的電子產(chǎn)品,在無載狀態(tài)下的功率量測(cè)規(guī)范及后續(xù)量測(cè)資料分析處理方式做定義。EN 50564:2011的內(nèi)容是取得于IEC 62301:2011標(biāo)準(zhǔn),因此這兩個(gè)標(biāo)準(zhǔn)在功率量測(cè)規(guī)范及后續(xù)量測(cè)資料分析處理方式是相同的。 Chroma 66202數(shù)位功率表是可以*符合EN 50564:2011在B.2.1章節(jié)對(duì)于功率量測(cè)設(shè)備所規(guī)范的要求,除此之外66202也可以*符合4.4.1章節(jié)對(duì)于功率量測(cè)不確定度要求部份?;旧?6202已通過KEMA實(shí)驗(yàn)室檢驗(yàn)為符合IEC 62301:2005針對(duì)功率量測(cè)需求的功率表,目前已確認(rèn)在300V x 100mA檔位的功率量測(cè)準(zhǔn)確度規(guī)格為0.1% Reading + 0.05% Range是小于EN 50564:2011所定義的不確定功率0.02W。
* Model 66200 ENERGY STAR-Power Test Soft Panel Download Chroma's 66200 Series Digital Power Meter is designed for single-phase measurements of AC power signals and related parameters common to most electronic products. Instead of traditional analog measurement circuits, the 66200 uses state-of-the-art DSP digitizing technology. The internal 16 bits analog/digital converters with sampling rates of up to 240kHz provide both high speed and high accuracy measurements which is unprecedented within the industry for this class of power meters current on the market.
型號(hào)66201為基本功能的機(jī)種,專為小功率產(chǎn)品測(cè)試使用,例如電池充電器、電壓適調(diào)器、LCD監(jiān)視器等??闪繙y(cè)參數(shù)包括了 :1. Voltage : Vrms, Vpeak+, Vpeak-2. Current : Irms, Ipeak+, Ipeak-3. Power : Watts, Power Factor, Apparent Power VA, Reactive Power VAR4. Current Crest Factor Frequency 型號(hào)66202數(shù)位功率表內(nèi)部有兩組量測(cè)電流感測(cè)器,可滿足小電流的量測(cè)精準(zhǔn)要求,也可適用大電流的應(yīng)用。除了型號(hào) 66201可量測(cè)的參數(shù)外,66202還可以測(cè)量涌浪電流(Inrush Current),總諧波失真率(Total Harmonic Distortion)及能量(焦耳)。因?yàn)槎嗔诉@些功能,66202更能滿足研發(fā)部門或品管部門的量測(cè)需求。 66200系列不僅提供平均模式,也提供了移動(dòng)視窗法,讓使用者設(shè)定時(shí)間長度,量測(cè)時(shí)會(huì)計(jì)算視窗內(nèi)所有資料,所以不會(huì)遺漏任何訊號(hào)。除此之外也提供能量累積模式(INTEGRATION MODE)來量測(cè)功率,符合能源之星測(cè)試要求。
The instruments include a four part display with 7-segment LED front panel readouts. Users can easily select desired parameters and readouts at a touch of a button. Instruments also include optional remote control using USB or GPIB interfaces via rear panel connections. The 66200 is packaged in a 2U high, half rack enclosure suitable for benchtop or system integration. The Model 66201 includes simple measurement functions designed for low power applications (maximum current 2A). Examples of these devices are AC adapters, battery chargers, LCD monitors, and similar devices. Included measurement data is as following : 1. Voltage : Vrms, Vpeak+, Vpeak- 2. Current : Irms, Ipeak+, Ipeak- 3. Power : Watts, Power Factor, Apparent Power VA, Reactive Power VAR 4. Current Crest Factor & Frequency The Model 66202 includes a 2-shunt design to provide highly accurate readings for both low and high current measurements. In addition to the parameters measured by Model 66201, the 66202 includes Inrush current, Total Harmonic Distortion of V/I, and Energy measurements. With these practical functions, the Model 66202 is suitable for the most demanding of R&D and quality control departments.
Model 66200 series 數(shù)位式功率表 Model 66200 series Digital Power Meter
Key Features: 3 in 1 Tester : AC, DC, IR Programmable output voltage to 5kV AC and 6kV DC Trip current programmable to 30mA AC and 10mA DC Insulation resistance to 50GΩ/1000V DC Built-in 8 channel SCANNER (19053 only) Built-in 4 channel SCANNER (19054 only) Open/Short Check (OSC) Ground Fault Interrupt (GFI) ARC detection (Flashover) Storage of 50 Tests Setups with 100 Steps per setup Optional transformer test fixture (19053 only) Standard RS-232 Interface Optional GPIB Interface
The Chroma Hipot Tester 19050 series provide 3 models for choice. The 19052 for AC/DC/IR Hipot testing and insulation resistance (IR) measurements, the 19053 which combines both AC and DC Hipot tests and IR measurements with 8HV scan channel capability into a single compact unit, and the 19054 which combines both AC and DC Hipot tests and IR measurements with 4HV scan channel capability into a single compact unit. The front panels of the fevers make them easy to operate. Digital display and user friendly control allows test parameters and limits to be set easily without the high voltage activating.
Key Features: Compact size Hipot tester Three instruments in one: AC Hipot, DC Hipot, Insulation Resistance (19073) Open/Short Check (OSC) ARC detection (Flashover) Provide reliable and stable test results Storage of 10 Tests Setups with 60 Steps per setup Ground Fault Interrupt (GFI)
Chroma 19070 series are the smallest Hipot Testers currently available in the world. Its super mini size is easy to carry and the large LCD display is suitable for viewing measurement results. These sophisticate Hipot Testers are most applicable to safety test for electronic components.